cylinders

Cylinder force.

Push and pull force a cylinder develops at a given pressure.

Push F = p × π·D²/4 Pull F = p × π·(D² − d²)/4
Push force (extend) —
Pull force (retract) —
Bore area —
Annulus area —
cylinders

Cylinder pressure required.

Pressure needed to push or pull a known load.

p = F ÷ A
Pressure to push —
Pressure to pull —
cylinders

Cylinder bore size.

Minimum bore to generate a required force at your system pressure.

D = √(4F ÷ πp)
Minimum bore —
Next standard bore (ISO 3320) —
cylinders

Cylinder speed.

Extend and retract speed for a given flow.

v = Q ÷ A
Extend speed —
Retract speed —
cylinders

Cylinder flow required.

Flow needed to hit a target cylinder speed.

Q = v × A
Flow to extend —
Flow to retract —
cylinders

Cylinder volume & cycle time.

Oil volume per stroke and how long each stroke takes.

V = A × stroke t = V ÷ Q
Volume to extend —
Volume to retract —
Extend time —
Retract time —
pumps

Pump flow.

Actual output flow from pump displacement and drive speed.

Q = Vg × n × ηv
Pump flow —
pumps

Pump displacement required.

Pump size needed to deliver a target flow.

Vg = Q ÷ (n × ηv)
Displacement —
pumps

External gear pump displacement.

Measure the gears and pump body, and get the displacement in cc per revolution.


0
—
DWL
pumps

Pump input power.

Motor or engine power needed to drive the pump.

P = (Q × p) ÷ ηt
Input power —
pumps

Pump drive torque.

Torque required at the pump shaft.

T = (Vg × p) ÷ (2π × ηm)
Drive torque —
motors

Motor torque.

Output torque from a hydraulic motor.

T = (Vg × Δp × ηm) ÷ 2π
Output torque —
motors

Motor speed.

Shaft speed of a hydraulic motor at a given flow.

n = (Q × ηv) ÷ Vg
Motor speed — rpm
motors

Motor flow required.

Flow needed to spin a motor at a target speed.

Q = (Vg × n) ÷ ηv
Required flow —
motors

Motor displacement required.

Motor size needed to deliver a target torque.

Vg = (2π × T) ÷ (Δp × ηm)
Displacement —
motors

Motor output power.

Mechanical power at the motor shaft.

P = T × 2πn ÷ 60
Output power —
power & heat

Hydraulic power.

Fluid power carried by flow at pressure.

P = Q × p
Hydraulic power —
power & heat

Heat generation.

Power lost as heat that your cooling system has to get rid of.

Heat = (Q × p ÷ ηt) × (1 − ηt)
Input power —
Heat load —
power & heat

Reservoir size.

Rule-of-thumb tank capacity. Industrial systems typically use 3–5 × pump flow per minute; mobile systems often 1–2 ×.

V = Q (per min) × factor
Minutes of pump flow held in the tank
Reservoir capacity —
hose & pipe

Fluid velocity.

Oil velocity in a hose, pipe or tube.

v = 4Q ÷ (π × ID²)
Fluid velocity —
Guide —
hose & pipe

Hose & pipe ID sizing.

Minimum inside diameter for a flow at a recommended velocity.

ID = √(4Q ÷ πv)
Minimum ID —
Nearest hose dash size (≥ ID) —
hose & pipe

Pressure drop in pipe.

Friction loss along a straight run of hose, pipe or tube (Darcy–Weisbach). Fittings and bends add more.

Δp = f × (L ÷ ID) × ρv² ÷ 2 Laminar f = 64/Re Turbulent f = 0.316/Re^0.25
ISO VG 46 ≈ 46 cSt at 40 °C
Velocity —
Reynolds number —
Flow regime —
Pressure drop —
accumulators

Accumulator sizing.

Gas-charged accumulator size to deliver a usable oil volume between two pressures (Boyle’s law).

V₀ = ΔV ÷ [(P₀/P₁)^(1/n) − (P₀/P₂)^(1/n)] (pressures absolute)
Accumulator size —
Typical pre-charge (0.9 × P₁) —
tube & Barlow

Barlow’s formula.

Burst and working pressure of tube or pipe, or the wall thickness you need. Uses outside diameter for a conservative result.

P = 2 × S × t ÷ OD Working P = Burst P ÷ safety factor
4:1 is typical for hydraulic tube
Burst pressure —
Pressure at yield —
Max working pressure —
unit converter

Unit converter.

Quick conversions between metric and imperial hydraulic units.

Showing 12 of 25 calculators

Good to know. These calculators give theoretical values for guidance only. Real-world results depend on component efficiencies, fluid temperature, fittings, duty cycle and operating conditions. Always check your design against manufacturer data and the relevant standards, apply appropriate safety factors, and never exceed the rated working pressure of any component. Pressures are gauge unless stated otherwise. If safety is on the line, talk to a qualified hydraulic engineer.

Formulas behind the tools.

Cylinders

Push force is pressure times bore area, F = p × πD²/4. Pull force uses the annulus, F = p × π(D² − d²)/4. Speed is flow divided by area; volume per stroke is area times stroke. The bore-size tool reports the next standard size from ISO 3320.

Pumps & Motors

Flow Q = Vg × n × ηv. Input power P = (Q × p) / ηt. Shaft torque T = (Vg × p) / (2π × ηm) for a pump, with mechanical efficiency on the output side for a motor. The external gear pump tool estimates displacement from tip diameter D, face width W and figure-8 bore length L for two standard spur gears at a 20° pressure angle.

Hose, Pipe, & Tube

Fluid velocity v = 4Q / (π × ID²). Rule-of-thumb limits are about 1 m/s on suction, 3 m/s on return and 4.5–6 m/s on pressure lines. Straight-pipe pressure drop uses Darcy–Weisbach. Barlow’s formula rates tube as P = 2 × S × t / OD, with working pressure equal to burst divided by the safety factor (typically 4:1).

Power, Heat, & Accumulators

Hydraulic power is P = Q × p. Heat load is the fraction of input power lost to inefficiency. Reservoir sizing is a rule of thumb: industrial tanks often hold 3–5 minutes of pump flow; mobile tanks 1–2. Accumulator size uses Boyle’s law on absolute pressures, isothermal (n = 1) or adiabatic (n = 1.4).

Rock solid trust in our services.

FluidKraft Trade & On Call place picture
4.9
Based on 34 reviews
Mark Hed.o. profile picture
Mark Hed.o.
4 years ago
Clinton Forner profile picture
Clinton Forner
4 years ago
Thanks Chris and Josh for the awesome service. Your communication is excellent and when I arrived to pick up my cylinder I have to say in my 25 years in this industry I have never had a cylinder returned in such great condition. The gland was painted and the minimal scratches on my cylinder(which is to be expected) were all professionally touched up and painted. The paint was colour match as well. I have never had this done before. You will definitely be doing all of my cylinder work
Avaleisho Davis profile picture
Avaleisho Davis
4 years ago
Been there once before but wasn't sure. Good service by Chris and very good price. He repaired my hydraulic hose for the 3ton
Awesome..!!! The Word that best describes the Team RYCO. You guys are amazing. Timely Support, Commitment to work & Reliable Solutions & so on. Scott – Always approachable & helpful JOSH – The man with Skill & brain Kevin – The Speedster Chris – the man behind the show & Amazing support. Thanks Guys for backing up our business & lending me a helping hand whenever I'm in need of. Cheers to the entire team. Happy to work with always.
Imad E profile picture
Imad E
5 years ago
Great staff
Peter Redondo profile picture
Peter Redondo
6 years ago
The team at Ryco Ingleburn have always delivered even on the most difficult of tasks. Knowledgeable and consistently delivering great quality on our cylinders and plant. Wouldn't go anywhere else. Thanks guys, great work.
Michael Jordan profile picture
Michael Jordan
6 years ago
Hi all, Ryco is such a great team. Every time I have had hydraulic problems they simply keep me on the road. Great service and friendly people. Really appreciate having them backing my business. Regards Michael – Ninja Skip Bins
Wade Base Zero profile picture
Wade Base Zero
7 years ago
When our cylinder spat the dummy and bled out, I called Chris at RYCO Ingleburn. Chris, Billy and the team were very professional and had us back on the road within the time frame requested. They even stayed back late, just to make sure we were satisfied. Thanks guys! May 2019 The team at Ryco Ingleburn have just completed another repair job for us. I honestly have not previously found a team that is so professional and solutions focused. These guys were able to replace our busted cylinders, install a new Power pack, Isolator switch & Pendent controller in only 2 Days.

Hydraulic calculator FAQs.

No. They give theoretical values for guidance only. Real-world results depend on component efficiencies, fluid temperature, fittings, duty cycle and operating conditions. Always check your design against manufacturer data and the relevant standards, apply appropriate safety factors, and never exceed the rated working pressure of any component. If safety is on the line, talk to a qualified hydraulic engineer.

Every calculator works in both metric and imperial. Use the metric / imperial toggle at the top of the grid to switch defaults (mm, bar, L/min, kW versus in, psi, US gpm, hp). You can still change the unit on any individual field.

Use Fluid velocity to check an existing ID, or Hose & pipe ID sizing to get a minimum inside diameter from flow and a recommended velocity (about 1 m/s suction, 3 m/s return, 4.5–6 m/s pressure). The result also suggests the nearest hose dash size. FluidKraft can then manufacture the hose assembly at our Trade counter or you can contact us to book service with our On Call team.

Measure gear tip diameter D, gear face width W, and the length L of the figure-8 gear bore across both gears. The tool estimates displacement in cc/rev for two identical standard spur gears at a 20° pressure angle, and shows the implied tooth count. It is an approximation — confirm against the pump nameplate or manufacturer data.

Yes. Our hydraulic calculators use the same formulas our engineers rely on every day to design and manufacture hydraulic systems and components. As long as the values you enter are accurate, the results are a reliable basis for a quote. Send us your figures and our team will review them, confirm the details, and prepare your quotation.